If two or more recirculating units are arranged next to or behind one another, they need to be ordered (matched in pairs) with the add-on designation GP.

The types in bold are standard. Types in size 12 are available on request.

Manufacturing Tolerances and Group Tolerances

Type Manufacturing tolerances in mm Group tolerances in µm within pairs
A B A B
SK 1, 2 0/-0.1 +/-0.005 2 2
SK 3, 6, 9, 121) 0/-0.1 +/-0.005 3 3
SKD 6, 9, 121) 0/-0.1 +/-0.005 3 3
SKC 6, 9 0/-0.1 +/-0.005 3 3
SR 2 0/-0.1 +/-0.005 2 2
SR 3, 6, 9, 121) 0/-0.1 +/-0.005 3 3

1) Types of size 12 are only available on request

Matched recirculating units marking illustration

Markings

The recirculating units in the same group are designated with a number, i.e. the same number corresponds to the exact same tolerance group.

Recirculating unit number markings

NRT Markings

Type Manufacturing tolerance A Sorts in µm Markings
NRT -0.025 -20 to -25 white
-15 to -20 green
-10 to -15 yellow
-5 to -10 blue
0 to -5 red

Colored rings around the lube nipple mark the relevant tolerance group.

NRT color marking illustration