In every linear guideway, the cage can be shifted from the centre along the longitudinal axis. Cage creep reduces the optimal load distribution and requires a correction stroke to return the cage to a centered position. The correction stroke requires a large expense of energy.
The causes of cage creep
- High accelerations and speeds
- Vertical installation of the guideway
- Uneven load distribution
- Protruding cage
- Different heat expansion coefficients
- Design and installation (lacking rigidity and/or accuracy of the connecting structure)
The benefits of FORMULA-S
- No cage slipping and thus consistent load conditions
- Avoids correction strokes
- No force required for cage reset
- Accelerations up to 300 m/s² (30 g)
- Speed 1 m/s
- Easy to install and/or uninstall
- Extended service life
- Vacuum-compatible up to 10⁻⁷ mbar
Suitable for the following guideways
- RN 3, RN 4 and RN 6
- RNG 4, RNG 6 and RNG 9
FORMULA-S meets the requirements fully in respect of productivity and cost-effectiveness. It is very robust and consists of only a few components.
Connecting structure
In the case of the connecting structure, the thickness Smin should be taken into account. The remaining dimensions correspond to the guideways RN and RNG (see chapter 5, dimensions and load capacities).