Guideway Order Code

Guideway Order Code Structure

AMSABS 3B S [Size]-[Type]-[Accuracy]-[Holes]-[Reference]-[Length]-[L5]-[L10]-[Coating]

Parameter Code Description
Size 25, 35, 45, 55, 65 Guideway size
Type N Standard
C Cover strip
Accuracy class G0 Highly accurate ± 5 µm
G1 Very accurate ± 10 µm
G2 Accurate ± 20 µm
G3 Standard ± 30 µm
Mounting holes KC Standard straightness (Standard)
KT Threaded holes (tapped)
Reference surface R1 Reference surface at bottom
R2 Reference surface at top
Coating CN None (no coating)
CH Hard chromium

Guideway Order Example

AMSABS 3B S 35-N-G1-KC-R1-1500-18.5-18.5-CN

  • AMSABS 3B S 35 = AMSABS 3B Guideway Size 35
  • N = Standard
  • G1 = Very accurate
  • KC = Standard straightness
  • R1 = Reference surface at bottom
  • 1500 = Guideway length 1500mm
  • 18.5-18.5 = First/last hole positions
  • CN = No coating (not chrome-plated; hard chromium is CH)

Carriage Order Code

Carriage Order Code Structure

AMSABS 3B W [Size]-[Type]-[Reading head position]-[Accuracy]-[Preload]-[Reference]-[Coating]-[Lube connection]-[Factory lubrication]-[Interface]-[Configuration]

Parameter Code Description
Size 25, 35, 45, 55, 65 Carriage size
Type A Standard
B Standard long
C High-flat
D High-flat long
E High-flat side mounting (Size 25, 35 only)
F Flat (Size 25-55 only)
G Flat long (Size 25-55 only)
Reading head position P1 Right top
P3 Left bottom
Accuracy class G0 Highly accurate
G1 Very accurate
G2 Accurate
G3 Standard
Preload class V1 Low preload (3%)
V2 Medium preload (8%)
V3 High preload (13%)
Reference side R1 Reference bottom (below or right)
R2 Reference top (top or left)
Coating CN None
CH Hard chromium
Lubrication port position S10 Left center
S11 Top left
S12 Lower left side
S13 Upper left side
S20 Right center
S21 Top right
S22 Lower right side
S23 Upper right side
S49
Lubrication state LN Oil protect
LG Grease protect
LV Full greasing
Interface (read head connector) TMH Absolute, cable 0.3 m
TRH Absolute, cable 3 m
TSH Absolute, cable 3 m
TDC Absolute, Siemens Drive CLiQ®
Configuration (signal protocol) TSS Cycle synchronous serial interface (SSI)
TS1 Hybrid: cycle synchronous serial + analogue 1 Vpp
TS2 Siemens Drive CLiQ® communications protocol
TF1 FANUC Serial Interface
TM1 Mitsubishi Serial Interface

Carriage Order Example

AMSABS 3B W 35-A-G1-V1-S10-LV-TS1

  • AMSABS 3B W 35 = AMSABS 3B Carriage Size 35
  • A = Standard carriage
  • G1 = Very accurate
  • V1 = Low preload
  • S10 = Left center lubrication connection
  • LV = Full greasing
  • TS1 = Hybrid: cycle synchronous serial + analogue 1 Vpp configuration

Read Head Spare Part Order Code

Read Head Order Code Structure

[Qty]x SABS XB-MH-[Configuration]

Interface Code Type Description
TS1 Hybrid Hybrid: cycle synchronous serial + analogue 1 Vpp
TSS SSI Cycle synchronous serial interface (SSI)
TS2 Drive CLiQ® Siemens Drive CLiQ® communications protocol
TF1 FANUC FANUC Serial Interface
TM1 Mitsubishi Mitsubishi Serial Interface
TDC Siemens Siemens Drive CLiQ® interface

Read Head Order Example

1x SABS XB-MH-TS1

1 read head spare part with SSI interface

Standard First/Last Hole Positions by Size

Size L5/L10 (mm) L4 hole pitch (mm)
Size 2513.530
Size 3518.540
Size 452552.5
Size 5528.560
Size 653675

Complete Order Examples

Machine tool application (SSI interface)

  • Guideway:AMSABS 3B S 45-N-G1-KC-R1-2000-25-25
  • Carriage:AMSABS 3B W 45-B-P1-G1-V1-R1-CN-S11-LV-TRH-TS1 × 2
  • Cable:KAO 12-5 × 2

High-precision equipment application (Drive CLiQ® interface)

  • Guideway:AMSABS 3B S 35-N-G0-KC-R1-1500-18.5-18.5-CN
  • Carriage:AMSABS 3B W 35-A-P1-G0-V1-R1-CN-S10-LV-TDC-TS2 × 2
  • Cable:KAO 12-3 × 2

Ordering Notes

Important Reminders

  • AMSABS 3B carriages have built-in read heads; the output interface type must be specified
  • The absolute measuring system reads the position immediately upon power-up, with no homing required
  • For incremental measuring, select the AMS 3B series
  • Read heads can be replaced independently and ordered as spare parts
ESC