Other dimensions and characteristic curves available on request

myonic precision spring washers provide axial preload and position compensation for ball bearings. Below is the complete officially published FS series specification and characteristic curves; for dimensions or characteristic curves not covered in this catalog, please contact a myonic application engineer.

FS Spring Washer Specification Table

Material: stainless steel

Designation vs. Dimensions

Designation h+s
(±0.05 mm)
s*
(mm)
d3
(mm)
d4
(mm)
Suitable for ball bearings with
Inner diameter Outer diameter
mm inch mm inch
FS 1.5 × 30.400.081.602.903
FS 2 × 3.50.450.082.153.102.1250
FS 2.5 × 40.500.082.703.802.54.1562
FS 3 × 4.50.500.103.204.303.1250
FS 3.5 × 50.550.103.704.805
FS 4 × 60.650.124.205.754.15626
FS 4.5 × 6.350.600.124.806.10.1875.2500
FS 5 × 70.650.125.206.7557
FS 6 × 80.700.156.207.8068.3125
FS 7 × 90.900.157.208.7079
FS 8 × 100.850.188.209.708.312510
FS 9 × 111.150.189.2010.70911
FS 10 × 121.050.2010.2011.701012
FS 11 × 131.300.2011.2012.7013
FS 12 × 141.300.2212.2013.7014
FS 13 × 151.300.2213.2014.7015
FS 14 × 161.550.2514.2015.6516
FS 15 × 171.550.2515.2016.6517
FS 16 × 192.150.3016.2018.5519.7500

Note: h+s is the compressed total height (tolerance ±0.05 mm); s* is the thickness (tolerance below); d3 / d4 are the washer's inner/outer diameter (mm). "Suitable for ball bearings with" indicates the bearing inner/outer diameter (mm or inch) this spring washer is designed to match.

Thickness s* Tolerance Table

Thickness (mm) Tolerance (mm)
< 0.2± 0.01
< 0.3± 0.012
< 0.4± 0.015

Characteristic Curves

Measurement conditions: h+s at F = 0 N is measured with a measuring force of 0.36 N.

The characteristic curves show the experimentally determined mean values for non-preset precision spring washers.

Characteristic Curve Chart 1

FS Spring Washer Characteristic Curves Chart 1

Characteristic Curve Chart 2

FS Spring Washer Characteristic Curves Chart 2

Characteristic Curve Chart 3

FS Spring Washer Characteristic Curves Chart 3

For other dimensions or corresponding characteristic curves, please contact a myonic application engineer.