Designation Format

The complete type designation of the RDDS1 (Rotary Direct Drive System, class 1) uses the following format. Below, each field code and its meaning are matched to a color dot; underlined entries indicate the standard option.

RDDS1 - DxH - X - X - XX - X - X - C - B - R
RDDS1 = Type: Rotary Direct Drive System, class 1
DxH = Size: outer diameter × height [mm]
X = Running accuracy: S = standard (± 10 µm), H = high accuracy (< ± 10 µm, on request)
X = Mounting version: B = base plate, F = flange plate
XX = Connection version: 1st digit C = cable / P = plug / M = cable with tailored plug; 2nd digit A = axial bottom / U = radial up / D = radial down
X = Winding version: WL = low dynamic / WM = medium dynamic / WH = high dynamic
X = Encoder increments (1 Vpp): 3600 / 5400 / 9000 / 18000 / 24000 (dependent on type)
C = Cooling: C = cooling / blank = no cooling (omitted if not selected)
B = Brake
R = Cleanroom, on request
Within each field, underlined entries are the standard option. Not all combinations are technically possible; please confirm the desired type designation before ordering.

Field-by-Field Details

The table below lists, from left to right of the type designation, the position code, available codes and their meaning for each field.

Field Position code Code options Description
Type RDDS1 RDDS1 Rotary Direct Drive System, class 1
Size DxH DxH Outer diameter × height [mm]
Running accuracy X S Standard: ± 10 µm
H High: < ± 10 µm, on request
Mounting version X B Base plate
F Flange plate
Connection version XX C_ Cable connection (open end, 1 m)
P_ Plug connection
M_ Cable with tailored plug connector
_A Axial bottom
_U Radial up
_D Radial down
Winding version X WL Winding low dynamic
WM Winding medium dynamic
WH Winding high dynamic
Encoder increments (1 Vpp) X 3600 Dependent on type
5400
9000
18000
24000
Cooling C C / (blank) Cooling / no cooling (omitted if not selected)
Brake B B Brake
Cleanroom R R Cleanroom, on request
Underlines signalize the standard. Not all of the combinations are technically possible. Please ask for your desired designation in advance.
ESC